Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Front Cardiovasc Med ; 11: 1373310, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38601047

RESUMO

Objectives: Patients with atrial fibrillation (AF) have lower left atrial (LA) strain, which is a predictor for LA function. Here, we evaluated the prognostic value of LA strain to predict the rhythm outcome in patients with persistent AF undergoing LA cryoablation concomitant to minimally invasive mitral valve repair. Methods: Between 01/2016 and 12/2020, 72 patients with persistent AF underwent LA cryoablation during minimally invasive mitral valve surgery. All patients received a complete LA lesion set and left atrial appendage (LAA) closure with a clip. All patients received preoperative transthoracic echocardiography (TTE) with LA and left ventricular strain measurements. Preoperative LA and LV strain analysis was correlated with postoperative rhythm outcome. Results: The mean age of the patients was 66.9 ± 7.2 years, of whom 42 (58%) were male patients. No major ablation-related complications occurred in any of the patients. Successful LAA closure was confirmed by intraoperative echocardiography in all patients. The 1-year survival rate was 97%. Freedom from AF at 12 months was 72% and 68% off antiarrhythmic drugs. Preoperative LA strain values were statistically significantly higher in patients with freedom from AF at 12 months of follow-up (12.7% ± 6.9% vs. 4.9% ± 4.1%, p = 0.006). Preoperative LV strain value was not associated with postoperative rhythm outcome. In multivariate logistic regression analysis, LA strain (p < 0.001) and AF duration (p = 0.017) were predictors for freedom from AF at 12 months of follow-up. Conclusions: In our study, LA strain analysis predicted the rhythm outcome in patients with persistent AF undergoing concomitant surgical AF ablation. In the future, LA strain might be a useful tool to guide decision-making on ablation strategies in patients with persistent AF.

2.
ACS Appl Mater Interfaces ; 16(11): 13534-13542, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38447594

RESUMO

Prosthetic materials are a source of bacterial infections, with significant morbidity and mortality. Utilizing the bionic "Lotus effect," we generated superhydrophobic vascular prostheses by nanocoating and investigated their resistance to bacterial colonization. Nanoparticles were generated from silicon dioxide (SiO2), and coated vascular prostheses developed a nanoscale roughness with superhydrophobic characteristics. Coated grafts and untreated controls were incubated with different bacterial solutions including heparinized blood under mechanical stress and during artificial perfusion and were analyzed. Bioviability- and toxicity analyses of SiO2 nanoparticles were performed. Diameters of SiO2 nanoparticles ranged between 20 and 180 nm. Coated prostheses showed a water contact angle of > 150° (mean 154 ± 3°) and a mean water roll-off angle of 9° ± 2°. Toxicity and viability experiments demonstrated no toxic effects of SiO2 nanoparticles on human induced pluripotent stem cell-derived cardiomyocytes endothelial cells, fibroblasts, and HEK239T cells. After artificial perfusion with a bacterial solution (Luciferase+ Escherichia coli), bioluminescence imaging measurements showed a significant reduction of bacterial colonization of superhydrophobic material-coated prostheses compared to that of untreated controls. At the final measurement (t = 60 min), a 97% reduction of bacterial colonization was observed with superhydrophobic material-coated prostheses. Superhydrophobic vascular prostheses tremendously reduced bacterial growth. During artificial perfusion, the protective superhydrophobic effects of the vascular grafts could be confirmed using bioluminescence imaging.


Assuntos
Células-Tronco Pluripotentes Induzidas , Dióxido de Silício , Humanos , Dióxido de Silício/farmacologia , Dióxido de Silício/química , Propriedades de Superfície , Biônica , Células Endoteliais , Interações Hidrofóbicas e Hidrofílicas , Água/química , Escherichia coli
3.
Clin Res Cardiol ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466346

RESUMO

BACKGROUND: Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS: This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS: Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS: Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION: Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.

4.
Catheter Cardiovasc Interv ; 103(1): 194-201, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38037296

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS: Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS: Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION: Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.


Assuntos
Estenose da Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/terapia , Desenho de Prótese
5.
Front Cardiovasc Med ; 10: 1251055, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37745113

RESUMO

Background: The prevalence of young patients with cardiac implantable electronic devices (CIED) is steadily increasing, accompanied by a rise in the occurrence of complications related to CIEDs. Consequently, transvenous lead extraction (TLE) has become a crucial treatment approach for such individuals. Objective: The purpose of this study was to examine the characteristics and procedural outcomes of young patients who undergo TLE, with a specific focus on identifying independent risk factors associated with adverse events. Methods: All patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) were categorized into two groups based on their age at the time of enrollment: 45 years or younger, and over 45 years. A subgroup analysis was conducted specifically for the younger population. In this analysis, predictor variables for all-cause mortality, procedural complications, and procedural failure were evaluated using multivariable analyses. Results: We identified 160 patients aged 45 years or younger with a mean age of 35.3 ± 7.6 years and 42.5% (n = 68) female patients. Leading extraction indication was lead dysfunction in 51.3% of cases, followed by local infections in 20.6% and systemic infections in 16.9%. The most common device to be extracted were implantable cardioverter-defibrillators (ICD) with 52.5%. Mean number of leads per patient was 2.2 ± 1.0. Median age of the oldest indwelling lead was 91.5 [54.75-137.5] months. Overall complication rate was 3.8% with 1.9% minor and 1.9% major complications. Complete procedural success was achieved in 90.6% of cases. Clinical procedural success rate was 98.1%. Procedure-related mortality was 0.0%. The all-cause in-hospital mortality rate was 2.5%, with septic shock identified as the primary cause of mortality. Multivariable analysis revealed CKD (OR: 19.0; 95% CI: 1.84-194.9; p = 0.018) and systemic infection (OR: 12.7; 95% CI: 1.14-142.8; p = 0.039) as independent predictor for all-cause mortality. Lead age ≥ 10 years (OR: 14.58, 95% CI: 1.36-156.2; p = 0.027) was identified as sole independent risk factor for procedural complication. Conclusion: TLE in young patients is safe and effective with a procedure-related mortality rate of 0.0%. CKD and systemic infection are predictors for all-cause mortality, whereas lead age ≥ 10 years was identified as independent risk factor for procedural complications in young patients undergoing TLE.

6.
Front Cardiovasc Med ; 10: 1209184, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727306

RESUMO

Background: Valve-in-valve (ViV) transfemoral transcatheter aortic valve implantation (TAVI) for failing aortic surgical bioprostheses or transcatheter heart valves (THV) has demonstrated a reasonable clinical and hemodynamic efficacy. Traditionally, self-expanding (SE) supra-annular THV are considered to result in superior hemodynamics compared with balloon-expandable intra-annular THV after ViV. However, so far no data are found on latest-generation intra-annular SE THV for aortic ViV procedures which might be superior with regard to coronary access or subsequent valve reintervention. Aim: We herein aim to evaluate a latest-generation SE intra-annular THV for aortic ViV procedures. Materials and methods: Between May 2022 and November 2022, five consecutive patients (4/5 female with mean age of 76.2 years and mean Society of Thoracic Surgeons predicted risk of mortality score of 2.9%) received ViV TAVI using the Navitor system (Abbott, Chicago, IL, USA) for treatment of failing surgical bioprostheses or THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium 3 (VARC-3) definitions. Results: At 30 days, absence of mortality and VARC-3 adjudicated clinical endpoints were documented. Echocardiography at 30 days revealed complete absence of paravalvular leakage and single-digit mean transvalvular gradients (mean of 6.0 mmHg) in all patients. Conclusion: The investigated intra-annular SE THV results in excellent 30-day outcomes for aortic ViV procedures for failing surgical bioprostheses or THV. Despite the intra-annular design, hemodynamic results were excellent, even in small bioprostheses. Ease of use of this valve platform is reflected by only two cycles of resheathing in five ViV procedures with hemodynamic stability during all steps of valve deployment.

7.
Pacing Clin Electrophysiol ; 46(8): 815-823, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37461858

RESUMO

BACKGROUND: Device complications, such as infection or lead dysfunction necessitating transvenous lead extraction (TLE) are continuously rising amongst patients with transvenous implantable-cardioverter-defibrillator (ICD). OBJECTIVES: Aim of this study was to characterize the procedural outcome and risk-factors of patients with indwelling 1- and 2-chamber ICD undergoing TLE. METHODS: We conducted a subgroup analysis of all ICD patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) database. Predictors for procedural failure and all-cause mortality were assessed. RESULTS: We identified 842 patients with an ICD undergoing TLE with the mean age of 62.8 ± 13.8 years. A total number of 1610 leads were treated with lead dysfunction (48.5%) as leading indication for extraction, followed by device-related infection (45.4%). Lead-per-patient ratio was 1.91 ± 0.88 and 60.0% of patients had dual-coil defibrillator leads. Additional extraction tools, such as mechanical rotating dilator sheaths and snares were utilized in 6.5% of cases. Overall procedural complications occurred in 4.3% with 2.0% major complications and a procedure-related mortality of 0.8%. Clinical success rate was 97.9%. All-cause in-hospital mortality was 3.4%, with sepsis being the leading cause for mortality. Multivariate analysis revealed lead-age ≥10 years (OR:5.82, 95%CI:2.1-16.6; p = .001) as independent predictor for procedural failure. Systemic infection (OR:9.57, 95%CI:2.2-42.4; p < .001) and procedural complications (OR:8.0, 95%CI:2.8-23.3; p < .001) were identified as risk factors for all-cause mortality. CONCLUSIONS: TLE is safe and efficacious in patients with 1- and 2-chamber ICD. Although lead dysfunction is the leading indication for extraction, systemic device-related infection is the main driver of all-cause mortality for ICD patients undergoing TLE.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Pessoa de Meia-Idade , Idoso , Criança , Desfibriladores Implantáveis/efeitos adversos , Fatores de Risco , Remoção de Dispositivo/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos
8.
J Cardiovasc Electrophysiol ; 34(9): 1951-1960, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37493496

RESUMO

INTRODUCTION: In an aging population with cardiac implantable electronic devices, an increasing number of octo- and even nonagenarians present for lead extraction procedures. Those patients are considered at increased risk for surgical procedures including lead extraction. Here, we investigated safety and efficacy of transvenous lead extraction in a large patient cohort of octo- and nonagenarians. METHODS AND RESULTS: A subgroup analysis of all patients aged ≥80 years (n = 499) in the German Laser Lead Extraction Registry (GALLERY) was performed. Outcomes were compared to the nonoctogenarians from the registry. Primary extraction method was Laser lead extraction, with additional use of mechanical rotational sheaths or femoral snares, if necessary. An analysis of patient- and device characteristics, as well as an assessment of predictors for adverse events via multivariate analyses was conducted. Mean patients age was 84.3 ± 3.7 years in the octogenarians group and 64.1 ± 12.4 years in the nonoctogenarians group. The median lead dwell time was 118.0 months (78; 167) and 92.0 months [60; 133], p < .001 in the octogenarians and nonoctogenarians group, respectively. Clinical procedural success rate was achieved in 97.6% of the cases in octogenarians and 97.9% in nonoctogenarians (p = .70). Overall complication rate was 4.4% in octogenarians and 4.3% in nonoctogenarians (0.91). In octogenarians procedure-related mortality was 0.8% and all-cause in-hospital mortality was 5.4%, while in nonoctogenarians, procedure related and all-cause in-hospital mortality were 0.5% and 3.1%, respectively. A body mass index (BMI) <20 kg/m2 , was the only statistically significant predictor for procedure-related complications in octogenarians, while systemic infection, BMI ≤20 kg/m2 , procedural complications and chronic kidney disease were predictors for in-hospital mortality. CONCLUSIONS: Laser lead extraction in octo- and nonagenarians is safe and effective. BMI ≤20 kg/m2 was the only statistically significant predictor for procedural complications. According to our data, advanced age should not be considered as contraindication for laser lead extraction.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Idoso de 80 Anos ou mais , Humanos , Remoção de Dispositivo/efeitos adversos , Lasers , Nonagenários , Sistema de Registros , Resultado do Tratamento , Octogenários
9.
J Clin Med ; 12(12)2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-37373789

RESUMO

BACKGROUND: The incidence of cardiac implantable electronic device (CIED)-related complications, as well as the prevalence of obesity, is rising worldwide. Transvenous laser lead extraction (LLE) has grown into a crucial therapeutic option for patients with CIED-related complications but the impact of obesity on LLE is not well understood. METHODS AND RESULTS: All patients (n = 2524) from the GermAn Laser Lead Extraction RegistrY (GALLERY) were stratified into five groups according to their body mass index (BMI, <18.5; 18.5-24.9; 25-29.9; 30-34.9; ≥35 kg/m2). Patients with a BMI ≥ 35.0 kg/m2 had the highest prevalence of arterial hypertension (84.2%, p < 0.001), chronic kidney disease (36.8%, p = 0.020) and diabetes mellitus (51.1%, p < 0.001). The rates for procedural minor (p = 0.684) and major complications (p = 0.498), as well as procedural success (p = 0.437), procedure-related (p = 0.533) and all-cause mortality (p = 0.333) were not different between groups. In obese patients (BMI ≥ 30 kg/m2), lead age ≥10 years was identified as a predictor of procedural failure (OR: 2.99; 95% CI: 1.06-8.45; p = 0.038). Lead age ≥10 years (OR: 3.25; 95% CI: 1,31-8.10; p = 0.011) and abandoned leads (OR: 3.08; 95% CI: 1.03-9.22; p = 0.044) were predictors of procedural complications, while patient age ≥75 years seemed protective (OR: 0.27; 95% CI: 0.08-0.93; p = 0.039). Systemic infection was the only predictor for all-cause mortality (OR: 17.68; 95% CI: 4.03-77.49; p < 0.001). CONCLUSIONS: LLE in obese patients is as safe and effective as in other weight classes, if performed in experienced high-volume centers. Systemic infection remains the main cause of in-hospital mortality in obese patients.

10.
Front Cardiovasc Med ; 10: 1158248, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37332585

RESUMO

Objectives: Implantation of implantable cardioverter defibrillators (ICD) reduces the risk of all-cause mortality in symptomatic heart failure (HF) patients with severe left ventricular (LV) dysfunction. Nevertheless, the prognostic impact of ICD therapy in continuous flow left ventricular assist device (LVAD) recipients remains controversial. Methods: 162 consecutive HF patients, who underwent LVAD implantation at our institution between 2010 and 2019, were categorized according to the presence (n = 94, ICD-group) or absence (n = 68, Control-group) of ICDs. Apart from clinical baseline and follow-up parameters, adverse events (AEs) related to ICD therapy and overall survival rates were retrospectively analyzed. Results: Out of 162 consecutive LVAD recipients 79 patients (48.8%) were preoperatively categorized as Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile ≤2. The prevalence of severe HF symptoms and preoperative use of short-term circulatory support devices (54.4% vs. 13.8%, p < 0.001) was higher within the Control-group, although baseline severity of LV and RV dysfunction was similar. Apart from an increased prevalence of perioperative right heart failure (RHF) within the Control-group (45.6% vs. 17.0%; p < 0.001), procedural characteristics and perioperative outcome were similar. Overall-survival during a median follow-up of 14 (3.0-36.5) months was similar within both groups (p = 0.46). During the first 2 years after LVAD implantation 53 ICD-related AEs occurred within the ICD-group. Thereof, lead-dysfunction occurred in 19 patients and unplanned ICD-reintervention in 11 patients. Furthermore, in 18 patients appropriate shocks without loss of consciousness occurred, whereas inappropriate shocks occurred in 5 patients. Conclusion: ICD therapy in LVAD recipients was not associated with a survival benefit or reduced morbidity after LVAD implantation. Conservative ICD-programming seems to be justified to avoid ICD-related complications and "awake shocks" after LVAD implantation.

11.
Dtsch Arztebl Int ; 120(33-34): 564-574, 2023 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-37097070

RESUMO

BACKGROUND: Perioperative arrhythmias are common depending on the type of the operation and can increase morbidity and mortality. METHODS: This review is based on pertinent publications retrieved by a selective search in PubMed, as well as the relevant European guidelines. RESULTS: Arrhythmias are seen in more than 90% of cardiac operations; they are usually transient and often asymptomatic. The risk factors for arrhythmia include ion channel diseases, old age, structural heart disease, cardiac surgery, noncardiac surgery with major fluid shifts, and pulmonary resection. The full spectrum of supraventricular and ventricular arrhythmias can arise perioperatively. Correct ECG interpretation, consideration of the arrhythmia in the overall clinical context, and an understanding of its causes, pathophysiology, and options for effective treatment are critically important. According to a meta-analysis, betablockers lower the risk of perioperative atrial fibrillation (OR = 0.56; 95% confidence interval: [0.35; 0.91]). If anticoagulant treatment is not interrupted for surgery, there is less bleeding with direct oral anticoagulants than with vitamin K antagonists (relative risk: 0.62 [0.47; 0.82]). Moreover, clinical follow-up is important, especially for patients with new-onset atrial fibrillation or heart failure. CONCLUSION: The identification of high-risk patients and the provision of individualized perioperative monitoring are essential aspects of patient safety. Outpatient cardiological follow-up can improve outcomes.


Assuntos
Fibrilação Atrial , Cardiopatias , Humanos , Fibrilação Atrial/diagnóstico , Hemorragia
12.
J Clin Med ; 12(8)2023 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-37109251

RESUMO

Objective: At the tissue level, disruption of the extracellular matrix network leads to irreversible cardiac fibrosis, which contributes to myocardial dysfunction. At the myocyte level, downregulation of beta-adrenoceptors (beta-AR) reduces adaptation to increased workload. The aim of our study was to analyse the correlation between myocardial fibrosis and beta-AR sensitivity in patients with aortic valve (AV) disease. Methods: A total of 92 consecutive patients who underwent elective AV surgery between 2017-2019 were included in our study (51 with aortic regurgitation (AR-group); 41 with aortic stenosis (AS-group) and left ventricular (LV) biopsies were obtained intraoperatively. In vitro force contractility testing was performed by measuring beta-AR sensitivity (-log EC50[ISO]). In parallel, a quantitative analysis of myocardial fibrosis burden was performed. Results: Mean age at the time of AV surgery was not statistically different in both groups (AR: 53.3 ± 15.3 years vs. AS: 58.7 ± 17.0 years; p = 0.116). The LV end-diastolic diameter was significantly enlarged in the AR-group when compared to the AS-group (59.4 ± 15.6 vs. 39.7 ± 21.2; p < 0.001). Analysis of beta-AR sensitivity (AR: -6.769 vs. AS: -6.659; p = 0.316) and myocardial fibrosis (AR: 8.9% vs. AS: 11.3%; p = 0.284) showed no significant differences between patients with AS and AR. There was no correlation between myocardial fibrosis and beta-AR sensitivity in the whole study cohort (R = 0.1987; p = 0.100) or in the AS-subgroup (R = 0.009; p = 0.960). However, significant correlation of fibrosis and beta-AR sensitivity was seen in AR-patients (R = 0.363; p = 0.023). Conclusion: More severe myocardial fibrosis was associated with reduced beta-AR sensitivity in patients presenting with AR but not with AS. Therefore, our results suggest that in patients with AR, cellular myocardial dysfunction is present and correlates with the extent of myocardial fibrosis in the myocardium.

13.
Front Cardiovasc Med ; 10: 1129410, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36970346

RESUMO

Background: Atrial fibrillation (AF) is common in patients with heart failure resulting in a high prevalence of AF in patients receiving Cardiac Resynchronization Therapy (CRT) implantation. In patients, unsuitable for transvenous left ventricular (LV)-lead implantation, epicardial LV-lead implantation represents a valuable alternative. Epicardial LV-lead placement can be achieved totally thoracoscopical or via minimally invasive left lateral thoracotomy. In patients with atrial fibrillation, concomitant left atrial appendage (LAA) clipping is feasible via the same access. Therefore, the aim of our study was the analysis of safety and efficacy of epicardial LV lead implantation and concomitant LAA clipping via minimally invasive left-lateral thoracotomy. Methods: Between December 2019 and March 2022, 8 patients received minimally invasive left atrial LV-lead implantation with concomitant LAA closure using the AtriClip. Transesophageal echocardiography (TEE) was performed to intraoperatively guide and control LAA closure. Results: Mean patients age was 64 ± 11.2 years, 67% were male patients. Minimally invasive left-lateral thoracotomy was used in 6 patients while a totally thoracoscopic approach was performed in 2 cases. Epicardial lead implantation was successfully performed in all patients with good pacing threshold (mean 0.8 ± 0.2 V) and sensing values (10.1 ± 2.3 mV). Posterolateral position of the LV lead was achieved in all patients. Furthermore, successful LAA closure was confirmed during TEE in all patients. No procedure-related complications occurred in any of the patients. Two patients additionally received simultaneous laser lead extraction during the same procedure. Complete lead extraction was achieved in both patients. All patients were extubated in the OR and had an uneventful postoperative course. Conclusion: Our study highlights a novel treatment approach for patients with atrial fibrillation and the necessity of epicardial LV leads. Placement of a posterolateral LV lead position with concomitant occlusion of the left atrial appendage via a minimally-invasive left-lateral thoracotomy or even a totally thoracoscopic approach is safe and feasible with superior cosmetic result and complete occlusion of the left atrial appendage.

14.
Eur Heart J ; 44(27): 2483-2494, 2023 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-36810794

RESUMO

AIMS: Atrial fibrillation (AF) is associated with altered cAMP/PKA signaling and an AF-promoting reduction of L-type Ca2+-current (ICa,L), the mechanisms of which are poorly understood. Cyclic-nucleotide phosphodiesterases (PDEs) degrade cAMP and regulate PKA-dependent phosphorylation of key calcium-handling proteins, including the ICa,L-carrying Cav1.2α1C subunit. The aim was to assess whether altered function of PDE type-8 (PDE8) isoforms contributes to the reduction of ICa,L in persistent (chronic) AF (cAF) patients. METHODS AND RESULTS: mRNA, protein levels, and localization of PDE8A and PDE8B isoforms were measured by RT-qPCR, western blot, co-immunoprecipitation and immunofluorescence. PDE8 function was assessed by FRET, patch-clamp and sharp-electrode recordings. PDE8A gene and protein levels were higher in paroxysmal AF (pAF) vs. sinus rhythm (SR) patients, whereas PDE8B was upregulated in cAF only. Cytosolic abundance of PDE8A was higher in atrial pAF myocytes, whereas PDE8B tended to be more abundant at the plasmalemma in cAF myocytes. In co-immunoprecipitation, only PDE8B2 showed binding to Cav1.2α1C subunit which was strongly increased in cAF. Accordingly, Cav1.2α1C showed a lower phosphorylation at Ser1928 in association with decreased ICa,L in cAF. Selective PDE8 inhibition increased Ser1928 phosphorylation of Cav1.2α1C, enhanced cAMP at the subsarcolemma and rescued the lower ICa,L in cAF, which was accompanied by a prolongation of action potential duration at 50% of repolarization. CONCLUSION: Both PDE8A and PDE8B are expressed in human heart. Upregulation of PDE8B isoforms in cAF reduces ICa,L via direct interaction of PDE8B2 with the Cav1.2α1C subunit. Thus, upregulated PDE8B2 might serve as a novel molecular mechanism of the proarrhythmic reduction of ICa,L in cAF.


Assuntos
Fibrilação Atrial , Humanos , Cálcio/metabolismo , Diester Fosfórico Hidrolases/metabolismo , Miócitos Cardíacos/fisiologia , Fosforilação
15.
J Mol Cell Cardiol ; 176: 1-10, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36681268

RESUMO

AIMS: The incidence of atrial fibrillation (AF) increases with age. Women have a lower risk. Little is known on the impact of age, sex and clinical variables on action potentials (AP) recorded in right atrial tissue obtained during open heart surgery from patients in sinus rhythm (SR) and in longstanding AF. We here investigated whether age or sex have an impact on the shape of AP recorded in vitro from right atrial tissue. METHODS: We performed multivariable analysis of individual AP data from trabeculae obtained during heart surgery of patients in SR (n = 320) or in longstanding AF (n = 201). AP were recorded by sharp microelectrodes at 37 °C at 1 Hz. Impact of clinical variables were modeled using a multivariable mixed model regression. RESULTS: In SR, AP duration at 90% repolarization (APD90) increased with age. Lower ejection fraction and higher body mass index were associated with smaller action potential amplitude (APA) and maximum upstroke velocity (Vmax). The use of beta-blockers was associated with larger APD90. In tissues from women, resting membrane potential was less negative and APA as well as Vmax were smaller. Besides shorter APD20 in elderly patients, effects of age and sex on atrial AP were lost in AF. CONCLUSION: The higher probability to develop AF at advanced age cannot be explained by a shortening in APD90. Less negative RMP and lower upstroke velocity might contribute to lower incidence of AF in women, which may be of clinical relevance.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Feminino , Idoso , Potenciais de Ação , Potenciais da Membrana , Átrios do Coração
16.
Heart Rhythm ; 20(2): 181-189, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36240993

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) has evolved as one of the most crucial treatment options for patients with cardiac device-related systemic infection (CDRSI). OBJECTIVE: The aim of this study was to characterize the procedural outcome and risk factors of patients with CDRSI undergoing TLE. METHODS: A subgroup analysis of patients with CDRSI of the GALLERY (GermAn Laser Lead Extraction RegistrY) database was performed. Predictors for complications, procedural failure, and all-cause mortality were evaluated. RESULTS: A total of 722 patients (28.6%) in the GALLERY had "systemic infection" as extraction indication. Patients with CDRSI were older (70.1 ± 12.2 years vs 67.3 ± 14.3 years; P < .001) and had more comorbidities than patients with local infections or noninfectious extraction indications. There were no differences in complete procedural success (90.6% vs 91.7%; P = .328) or major complications (2.5% vs 1.9%; P = .416) but increased procedure-related (1.4% vs 0.3%; P = .003) and all-cause in-hospital mortality (11.1% vs 0.6%; P < .001) for patients with CDRSI. Multivariate analyses revealed lead age ≥10 years as a predictor for procedural complications (odds ratio [OR] 3.23; 95% confidence interval [CI] 1.58-6.60; P = .001). Lead age ≥10 years (OR 2.57; 95% CI 1.03-6.46; P = .04) was also a predictor for procedural failure. We identified left ventricular ejection fraction <30% (OR 1.70; 95% CI 1.00-2.99; P = .049), age ≥75 years (OR 2.1; 95% CI 1.27-3.48; P = .004), chronic kidney disease (OR 1.92; 95% CI 1.17-3.14; P = .01), and overall procedural complications (OR 5.15; 95% CI 2.44-10.84; P < .001) as predictors for all-cause mortality. CONCLUSION: Patients with CDRSI undergoing TLE demonstrate an increased rate of all-cause in-hospital, as well as procedure-related mortality, despite having comparable procedural success rates. Given these data, it seems paramount to develop preventive strategies to detect and treat CDRSI in its earliest stages.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Humanos , Criança , Idoso , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Cardiopatias/etiologia , Comorbidade , Remoção de Dispositivo/efeitos adversos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos
17.
Front Cardiovasc Med ; 10: 1342886, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38274307

RESUMO

Introduction: In CIED infections, all device material needs to be removed. But, especially in pacemaker-dependent patients it is often not possible to realize a device-free interval for infection remediation. In those patients, different treatment options are available, however the ideal solution needs still to be defined. Methods: This retrospective analysis includes 190 patients undergoing CIED extractions due to infection. Three different treatment algorithms were analyzed: Group 1 included 89 patients with system removal only (System removal group). In Group 2, 28 patients received an epicardial electrode during extraction procedure (Epicardial lead group) while 78 patients in group 3 (contralateral reimplantation group) received implantation of a new system contralaterally during extraction procedure. We analyzed peri- and postoperative data as well as 1-year outcomes of the three groups. Results: Patients in the system removal and epicardial lead groups were significantly older, had more comorbidities, and suffered more frequently from systemic infections than those in contralateral reimplantation group. Lead extraction procedures had comparable success rates: 95.5%, 96.4%, and 93.2% of complete lead removal in the System removal, Epicardial Lead, Contralateral re-implantation group respectively. Device reimplantation was performed in all patients in Epicardial lead and Contralateral reimplantation group, whereas only 49.4% in System removal group received device re-implantation. At 1-year follow-up, freedom from infection and absence of pocket irritation were comparable for all groups (94.7% Contralateral reimplantation group and Epicardial lead group, 100% System removal group). No procedure-related mortality was observed, whereas 1-year mortality was 3.4% in System removal group, 4.1% in Contralateral re-implantation group and 21.4% in Epicardial lead group (p < 0.001). Conclusion: In patients with CIED infection, systems should be removed completely and reimplanted after infection remediation. In pacemaker-dependent patients, simultaneous contralateral CIED re-implantation or epicardial lead placement may be performed, depending on route, severity and location of infection.

18.
Rev. bras. cir. cardiovasc ; 37(6): 949-951, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1407319

RESUMO

Abstract Sinus of Valsalva aneurysm is a rare cardiac abnormality which can be acquired or of congenital origin. A spontaneous rupture into the right atrium is possible and, if not adequately treated, may result in a progressive heart failure due to the left-to-right intracardiac shunt. If ruptured sinus of Valsalva aneurysm is diagnosed, surgical repair is indicated, and different surgical techniques have been reported. If concomitant aortic regurgitation is present, aortic valve replacement is usually performed. Herein, we describe an uncommon clinical presentation of a ruptured sinus of Valsalva aneurysm which has been corrected by aortic valve reimplantation.

19.
Medicina (Kaunas) ; 58(11)2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36363563

RESUMO

Background and Objectives: In patients with paroxysmal atrial fibrillation (AF) undergoing CABG or aortic valve surgery, many surgeons are not willing to open the left atrium to perform a complete left-sided Cox-Maze lesion set. Pulmonary vein isolation (PVI) is often favored in those patients. We investigated the outcome of patients with isolated pulmonary vein isolation compared to those receiving an extended left atrial (LA) lesion set. Materials and Methods: Between 2003 and 2016, 817 patients received concomitant surgical AF ablation in our institution. A total of 268 patients with paroxysmal AF were treated by surgical ablation concomitant to AVR or CABG. Of those, 86 patients underwent a complete left-sided lesion set, while 182 patients were treated with an isolated pulmonary vein isolation. The primary endpoint was freedom from atrial fibrillation at 12 months' follow-up. Results: There were no statistically significant differences regarding baseline characteristics. No major ablation-related complications were observed in any of the groups. In the PVI group, three patients (1.6%) had an intraoperative stroke, while two (2.3%) patients experienced a stroke in the LA ablation group (p = 0.98). In-hospital mortality was 3.4% in the PVI group, and 2.8% in the extended LA group (p = 0.33). Freedom from AF at 12 months' follow-up was 76% in the extended LA ablation group and 70% in the PVI group, showing no statistically significant difference (p = 0.32). Conclusion: Surgical AF ablation concomitant to CABG or AVR in patients with paroxysmal AF is safe and effective. There was no statistically significant difference between the compared lesion sets in terms of freedom from AF, survival or stroke rate after 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Acidente Vascular Cerebral , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ponte de Artéria Coronária , Acidente Vascular Cerebral/complicações , Recidiva
20.
Medicina (Kaunas) ; 58(11)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36422224

RESUMO

Background: Atrial fibrillation is the most common arrhythmia and has been described as driver of cardiovascular morbidity and risk factor for cardiac device-related complications, as well as in transvenous lead extraction (TLE). Objectives: Aim of this study was to characterize the procedural outcome and risk-factors of patients with atrial fibrillation (AF) undergoing TLE. Methods: We performed a subgroup analysis of all AF patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) database. Predictors for all-cause mortality were assessed. Results: A total number of 510 patients with AF were identified with a mean age of 74.0 ± 10.3 years. Systemic infection (38.4%) was the leading cause for TLE, followed by local infection (37.5%) and lead dysfunction (20.4%). Most of the patients (45.9%) presented with pacemaker systems to be extracted. The total number of leads was 1181 with a 2.3 ± 0.96 leads/patient. Clinical procedural success was achieved in 97.1%. Occurrence of major complications was 1.8% with a procedure-related mortality of 1.0%. All-cause mortality was high with 5.9% and septic shock being the most common cause. Systemic device infection (OR: 49.73; 95% CI: 6.56−377.09, p < 0.001), chronic kidney disease (CKD; OR: 2.67; 95% CI: 1.01−7.03, p = 0.048) and a body mass index < 21 kg/m2 (OR: 6.6; 95% CI: 1.68−25.87, p = 0.007) were identified as independent predictors for all-cause mortality. Conclusions: TLE in AF patients is effective and safe, but in patients with systemic infection the mortality due to septic shock is high. Systemic infection, CKD and body mass index <21 kg/m2 are risk factors for death in patient with AF undergoing TLE.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Cardiopatias , Insuficiência Renal Crônica , Choque Séptico , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Remoção de Dispositivo/efeitos adversos , Sistema de Registros , Cardiopatias/etiologia , Lasers , Insuficiência Renal Crônica/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...